RPC Runner

The rpc subcommand can be used to send and receive commands to local devices via serial and Bluetooth using Remote Procedure Calls (RPC).

In general, the tool uses the following process to run the command:

  1. Requests a connection to the target device from the gateway bridge

  2. Send the request to the target device

  3. Wait for the command response

  4. Disconnect from the target device

  5. Display the results

Note

Running RPCs requires a running instance of a Gateways bridge.

Supported Commands

The full list of currently supported commands can be displayed with infuse rpc --help:

> infuse rpc --help
usage: infuse rpc [-h] (--gateway | --id ID) [--conn-log] <command> ...

Run remote procedure calls on devices

options:
  -h, --help            show this help message and exit
  --gateway             Run command on local gateway
  --id ID               Infuse ID to run command on
  --conn-log            Request logs from remote device

commands:
  <command>
    application_info    Query basic application versions and state
    bt_connect_infuse   Connect to an Infuse-IoT Bluetooth device
    bt_disconnect       Disconnect from a Bluetooth device
    coap_download       Download a file from a COAP server (Infuse-IoT DTLS protected)
    data_logger_read    Read data from data logger
    data_logger_state   Get state of a data logger
    fault               Immediately trigger an exception on the device
    file_write_basic    Write a file to the device
    gravity_reference_update
                        Store the current accelerometer vector as the gravity reference
    kv_bt_peer          Configure the peer Bluetooth address
    kv_read             Read values from the KV store
    kv_reflect_crcs     Read KV store reflection crc values
    kv_write            Write an arbitrary kv value
    last_reboot         Retrieve information pertaining to the previous reboot
    lte_at_cmd          Run AT command against LTE modem
    lte_modem_info      Get LTE modem information
    lte_pdp_ctx         Set the LTE PDP context (IP family & APN)
    lte_state           Get current LTE interface state
    reboot              Reboot the device after a delay
    security_state      Query current security state and validate identity
    sym_read            Read arbitrary memory (NO ADDRESS VALIDATION PERFORMED)
    time_get            Get the current time knowledge of the device
    time_set            Set the current time of the device
    wifi_configure      Set the WiFi network SSID and PSK
    wifi_scan           Scan for WiFi networks
    wifi_state          Get current WiFi interface state
    zbus_channel_state  Query current state of zbus channel

Running Commands

Running a RPC on a remote device requires specifying the desired target device. This can be either --gateway to run the command on the local serial gateway device (no matter its ID), or --id $INFUSE_ID to specify a local Bluetooth device.

The target device is then followed by the desired command name and any command specific arguments.

> infuse rpc --id 0xcc0000eb1e000000 time_get
          Source: GNSS
     Remote Time: 2025-03-10 01:54:52.837
      Local Time: 2025-03-10 01:54:52.150
          Synced: 2193 seconds ago